1.
Journal of Practical Radiology ; (12): 1590-1593,1613, 2016.
Article in Chinese | WPRIM | ID: wpr-605439

ABSTRACT

Objective To investigate the implementation and application of rotational DSA dual volume technology in displaying the intracranial artery stent.Methods Firstly,the “stent opacity”single volume technology was used to display 5 types of stent which were released in 7 cases of pure intracranial artery stenting and 12 cases of stent-assisted aneurysm embolization.Then we applied “vessel translucent”and “vessel opacity”single volume technology to display corresponding vessel segments.Finally,by coalescing the single volume imaging of stent and vessel,the “vessel opacity + stent opacity”dual volume image and “vessel translucent+ stent opacity”dual volume image were performed.We compared the effects of two kinds of dual volume imaging and assessed the imaging characteristics and influencing factors of each method.Results (1)On the “stent opacity”single volume display mode,in 7 cases of pure intracranial artery stenting,the display effect of two Pipeline stents and three Apollo stents belongs to level 1,the display effect of two Enterprise stents belongs to level 2;In 12 cases of stent-assisted aneurysm embolization,in the stent segments which weren’t influenced by artifacts,the display effect of two LEVIS stents belongs to level 1,the display effects of 5 Enterprise stents and 2 Solitaire AB stents belongs to level 2;While in the stent segments which were influenced by the artifact of spring coil and bone,the display effect significantly reduced, three pieces of Enterprise stents were even unable to identify.(2)On the “vessel opacity”single volume display mode,1 9 cases of vessel segment at the stent completed opacity display.The surface structure of vessel was very clear,but the structure under the surface was completely being covered.On the “vessel translucent”single volume display mode,the surface structure of 19 cases of vessel segment at the stent displayed clear at the tangential position.The vessel lumen also presented transparent state.(3)On the “stent opacity+vessels opacity”double volume display mode,the start-stop location and the adherence of stents in blood vessels in 1 6 cases were displayed clearly. When using the “stent opacity+ vascular opacity”double volume imaging,except 3 cases which used ball expansion Apollo stents could display comprehensive relationship between the blood vessels,in the other 13 cases,the relationship between stent and vascular could not be fully displayed.Conclusion On the condition that the single volume display technology shows stent well,the “stent opaque+vessels translucent”double volume display technology can well present the stent condition in the vessels.

2.
Chinese Journal of Radiology ; (12): 367-370, 2012.
Article in Chinese | WPRIM | ID: wpr-418626

ABSTRACT

ObjectiveInvestigate the value and feasibility of image registration with reverse rotation in lateral cerebral DSA.Methods ( 1 ) Experimental study:the target images were subtracted directly,and subtracted again after reverse rotation.Software of registration and subtraction with reverse rotation edited by the author utilizing Visual Basic.The function of the automatic angle detection by the software were evaluated to see whether it detected the angle of line.The subtraction function of DSA by the software was evaluated.(2) Clinical retrospective study:the untreated mask and target inages of 15 patients with motion along vertical axis during lateral cerebral DSA were uploaded to the software.The target images were processed with and without the software to get two sets of images.( 3 ) Evaluation:four experienced radiologists read and compared the two sets of the images,and graded their findings.Results ( 1 ) The automatic detection by the software suggested that the target images should be rotated counterclockwise 1.3°. The subtraction result of the software was satisfactory.(2)In the 15 sets of images,there were only three sets of images deemed optimal after traditional subtraction.After reverse rotation,artifacts were significantly reduced and the image sharper. There were ten cases with significant artifacts after traditional subtraction,and those images were sharper and showed more peripheral vessels after reverse rotation. The traditional subtraction images of two sets could not be interpreted,the reverse rotation registration images reached the diagnostic quality.(3)Subjective evaluation: there were more information and less noise and distortion in the registration images with reverse rotation than in the traditional subtraction. But the image resolution decreased slightly after reverse rotation registration.ConclusionThe registration of digital angiography with reverse rotation can improve the image quality in lateral cerebral DSA.

SELECTION OF CITATIONS
SEARCH DETAIL